Phone: (325)-235-4276

Toll Free: (888)-800-8771

Email:

 

TECHNICAL PAPERS

 

Included below are links to technical papers referencing Eljen products or referencing products equivalent to Eljen's products.

 

EJ-254

  1. D. M. Drake et al., New electronically black neutron detectors. Nucl. Instrum. Methods Phys. Res. A274, 576-482 (1986).

EJ-276D (Formerly EJ-299-33A)

  1. S. Nyibule et al., Radioluminescent characteristics of the EJ-299-33 plastic scintillator. Nucl. Instrum. Methods Phys. Res. A728, 36-39 (2013).

EJ-301

  1. F. T. Kuchnir, F. J. Lynch, Time-dependence of scintillators and the effect on pulse-shape discrimination. IEEE Trans. Nucl. Sci. 15, 107-113 (1968).
  2. J. B. Czirr, The α/β ratio of several organic scintillators. Nucl. Instrum. Methods. 25, 106-108 (1963).
  3. R. A. Winyard, G. W. McBeth, Pulse shape discrimination in inorganic and organic scintillators, II. Nucl. Instrum. Methods. 98, 525-533 (1972).
  4. J. M. Adams, G. White, A versatile pulse shape discriminator for charged particle separation and its application to fast neutron time-of-flight spectroscopy. Nucl. Instrum. Methods. 156, 459-476 (1978).
  5. R. A. Cecil et al., Improved predictions of neutron detection efficiency for hydrocarbon scintillators from 1 MeV to about 300 MeV. Nucl. Instrum. Methods. 161, 439-447 (1979).
  6. A. Aksoy et al., Response-function measurement of an NE-213 scintillator using the 2H(d, n)3He reaction. Nucl. Instrum. Methods Phys. Res. A337, 486-491 (1994).
  7. V. V. Verbinski et al., Calibration of an organic scintillator for neutron spectrometry. Nucl. Instrum. Methods. 65, 8-25 (1968).
  8. L. Büermann et al., Response of NE-213 liquid scintillation detectors to high-energy photons (Eγ > 3 MeV). Nucl. Instrum. Methods Phys. Res. A332, 483-492 (1993).
  9. R. Koohi-Fayegh et al. Neural network unfolding of photon and neutron spectra using an NE-213 scintillation detector. Nucl. Instrum. Methods Phys. Res. A329, 269-276 (1993).

EJ-313

  1. S. Homma, S. Takemoto, Temperature dependence of scintillation pulses in anthracene and CsI(Tl). Rev. Sci. Instrum. 32, 1055 (1961).
  2. C. P. Jupiter, J. Parex, A study of the scintillation properties of various hydrogenous and non-hydrogenous solutes dissolved in hexafluorobenzene. IEEE Trans. Nucl. Sci. 13, 692-703 (1966).
  3. K. Ewen, B. Gonsior, Ein neutronenunempfindlicher γ-strahlungsdetektor. Nucl. Instr. Methods. 99, 573-578 (1972).

EJ-339

  1. L. W. Bollinger, G. E. Thomas, Boron-loaded liquid scintillation neutron detectors. Rev. Sci. Instrum. 28, 489-496 (1957).
  2. L. Von Sutterlin, Atomkernenergie. 12, 287-288 (1967).
  3. L. R. Greenwood, N. R. Chellew, Improved 10B-loaded liquid scintillator with pulse-shape discrimination. Rev. Sci. Instrum. 50, 466-471 (1979).